Simulink sample time with external sample clock?
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Brian Tremaine
le 17 Juil 2019
Commenté : Brian Tremaine
le 20 Juil 2019
Hi,
I want to run a S&H block with an external sample pulse. I am simulating a mixed signal digital PLL for a motor control. The phase detector is using boolean logic elements and is run from a 5Mhz pulse generator. The phase detector generates a phase count and a sample pulse about every 360Hz. I need this to drive a digital filter but am unclear how to use my boolean 360Hz sample pulse to act as the sample time for my z-domain digital filter.
Thanks ~
![Matlab_question.png](https://www.mathworks.com/matlabcentral/answers/uploaded_files/230251/Matlab_question.png)
0 commentaires
Réponse acceptée
Jonas
le 18 Juil 2019
I would suggest to put the digital filter in a triggered subsystem and use the 360 Hz signal as trigger.
Plus de réponses (0)