Effacer les filtres
Effacer les filtres

When is the 'ModelRefe​renceVersi​onMismatch​Message' Simulink model parameter editable?

7 vues (au cours des 30 derniers jours)
When I open a model's test harness, I receive the following error:
I would like to disable the "ModelReferenceVersionMismatchMessage" parameter, but when I go to the configuration parameters, it's greyed-out and I can't modify it. When I try to edit it from the command line, I also receive errors:
The documentation page for this parameter doesn't give any hints as to when it is possible to actually edit it. How can I edit it?

Réponse acceptée

Fangjun Jiang
Fangjun Jiang le 9 Avr 2020
Try this
model='sldemo_mdlref_basic';
open_system(model);
get_param(model,'ModelReferenceVersionMismatchMessage')
set_param(model,'ModelReferenceVersionMismatchMessage','warning')
set_param(model,'ModelReferenceVersionMismatchMessage','none')
  3 commentaires
Fangjun Jiang
Fangjun Jiang le 20 Avr 2020
Yes. In the .tlc file, you can disable certain configuration parameters. Open the .tlc file to see if you can find the source.
Monika Jaskolka
Monika Jaskolka le 20 Avr 2020
Modifié(e) : Monika Jaskolka le 20 Avr 2020
Thank you. You're right. I can enable the parameter by modifying the custom .tlc file like this:
slConfigUISetEnabled(hDlg, hSrc, 'ModelReferenceVersionMismatchMessage', 'true');