PID BLOCK IN SIMULINK
15 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Uzair Akhtar
le 13 Avr 2020
Commenté : Ameer Hamza
le 14 Avr 2020
I have worked out that my PID controller is
Gc = 4.2(1 + 1/1.57s + 0.39s)
I want to put this into a block on simulink but the PID controller block in simulink is in a weird form. Does anyone know how to get around this. Thanks.
0 commentaires
Réponse acceptée
Ameer Hamza
le 13 Avr 2020
In the Simulink PID block, In the form field, change the form from parallel to ideal and set the value of filter coefficient N to be quite high (say 200). Then parameters P, I, and D can be used from your current transfer function.
2 commentaires
Ameer Hamza
le 14 Avr 2020
PID block uses a low-pass filter for D term. The value of N controls the stop-band of the low-pass filter. Higher the value of N, higher is the stop-band frequency. For the low-value of N, the PID block will smooth the derivative of your system. If you have a high value of N, the filter will have no significant effect.
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur PID Controller Tuning dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!