- Create a subsystem. Inside the subsystem, place a constant block connected to an output port. Set the value of the constant block to be "K"
- Mask the subsystem
- Edit the subsystem mask. Add 3 "Edit" parameters. 1 for the bus name, the second for the bus element name. The third should have the name "K" and uncheck the "Visible" box.
- On the mask "Initialization", add code that:
- Creates an instance of the bus specified in the first parameter
- Searches the bus to find the bus element specified by the second parameter
- Sets the workspace mask variable "K" created in step 3 to be the min or max value of the bus element
Simulink: Access bus element properties
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Tom Dollfus
le 11 Mai 2020
Modifié(e) : Mark McBroom
le 14 Mai 2020
How to access one bus element properties (minimum and maximum values) in Simulink ? I would like to use these values to saturate a computed signal before assigning the signal.
Thanks
BR
0 commentaires
Réponse acceptée
Mark McBroom
le 14 Mai 2020
Modifié(e) : Mark McBroom
le 14 Mai 2020
Here is one approach that might work. It requires some knowledge of block masking.
0 commentaires
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Subsystems dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!