How to display internal signals in a Simulink Model?

I have a hierarchical design which has 6 levels and uses model referencing.When i simulate from the top level, the scopes in the internal models are not getting populated with the data. Is there a way in which i can display the internal signals in the referenced models without bringing them out?

2 commentaires

Is the Model reference block running in Accelerator mode? I would guess that if you changed it to Normal mode, the scopes will be populated.
Sivaram
Sivaram le 15 Juil 2013
Thanks. Yes, the referenced block is running in accelerator mode.I am using multiple instances of the same model in the design and the simulation throws an error if the mode is normal.

Connectez-vous pour commenter.

 Réponse acceptée

Kaustubha Govind
Kaustubha Govind le 17 Juil 2013

0 votes

I don't think the Scopes actually run when the model is running in Accelerated mode, because Simulink generates a C-MEX S-function for the model for run-time execution, and Scopes are not part of that S-function AFAIK. I think you need to configure the internal signals for logging if you'd like to examine them. For example, you could configure Test Points on the signals of interest.

Plus de réponses (0)

Catégories

En savoir plus sur Simulink Coder dans Centre d'aide et File Exchange

Produits

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by