I can not use functions for NI device
6 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
I found I can not use some functions when I tried to acquire data with ni product usb-6008.
for example,
s = daq.createSession('ni'),daq.getDevices,addAnalogInputChannel.
I can not use them, the error is: Undefined variable "daq" or class "daq.createSession". Undefined function or variable 'daq'.and so on. what's the matter?
0 commentaires
Réponses (3)
Walter Roberson
le 31 Juil 2013
You do not have the DAT installed, or not licensed, or you are using a version of MATLAB that does not support session based acquisition.
Which MATLAB release are you using?
Does
which -all daq
show any result?
2 commentaires
Walter Roberson
le 31 Juil 2013
The first support for session-based interfaces was R2010b, the release after the one you had. With your software you will need to use the legacy interface.
Note: not all NI devices were supported in R2010b; more devices were added with each release from R2010b.
mado
le 31 Juil 2013
Modifié(e) : mado
le 31 Juil 2013
2 commentaires
Walter Roberson
le 1 Août 2013
I already responded above. Your version does not support session-based interface at all.
Eric Keller
le 1 Août 2013
if you have a 32 bit system and can't upgrade matlab, use the legacy interface.