RF Blockset multiple testbenches
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
ToKa
le 18 Juin 2021
Réponse apportée : Kiran Felix Robert
le 21 Juin 2021
Hello,
I'd like to have two s-parameter testbenches on a simulink simulation. But when I simulate, the following error occurs:
"Two Terminate Function blocks '.../S-Parameter Testbench/Terminate Function' and '.../S-Parameter Testbench1/Terminate Function' are at the same non-virtual hierarchical level."
How can I simulate with two testbenches?
0 commentaires
Réponse acceptée
Kiran Felix Robert
le 21 Juin 2021
Hi ToKa,
Follow the steps to Look under the S-Parameter Testbench block's mask,
Right-Click on S-Parameter Testbench Block -> Locked Library Link -> Go To Library Block -> Right-Click on S-Parameter Testbench Block on the Library -> Look under Mask
While using multiple S-Parameter Testbench blocks in the same level of a model, there are multiple Terminate Function blocks in the same hierarchy, which causes a redundancy issue.
To solve this issue, the S-Parameter Testbenches can be grouped separately as atomic subsystems (one Block per Subsystem) which will resolve the redundancy.
To Group as an Atomic Subsystems,
Select all the blocks which are to be grouped > Right-Click > Create Subsystem from Selection > Right-Click on the newly created Subsystem > Block Parameters > Check the Checkbox on Treat as Atomic Unit.