Problem with connection
Afficher commentaires plus anciens
Hi... I create a model but appear the next error:
"The following two blocks cannot be connected in series because they are modeled as current sources:
Block 1: Ideal Switch1 Block 2: Subsystem/Controlled Current Source
Add a high-value resistance in parallel with one of the two block. You can also specify high-value resistive snubbers if the blocks have a snubber device."
The Ideal Switch1 and the Subsystem/Controlled Current Source was SimPowerSystems but what resistor i use to correct the error?
1 commentaire
Kaustubha Govind
le 27 Juin 2011
I don't have any experience with SimPowerSystems but you could possibly set a large value for the "Snubber resistance Rs" parameter in the Ideal Switch dialog, as the error message suggests.
Réponse acceptée
Plus de réponses (3)
Arnaud Miege
le 28 Juin 2011
3 votes
Just use a Series RLC Branch in parallel with your ideal switch, but keep everything on the SimPowerSystems side (i.e. the resistor should between ports 1 & 2 of the ideal switch).
HTH,
Arnaud
1 commentaire
Nuno
le 30 Juin 2011
Nuno
le 26 Juin 2011
0 votes
Nuno
le 28 Juin 2011
0 votes
Catégories
En savoir plus sur Power Converters dans Centre d'aide et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!