NI DAQ USB 6351 problem on win64 platform

3 vues (au cours des 30 derniers jours)
Tomaz79
Tomaz79 le 11 Juil 2011
Hi,
I'm trying to acquire data with a NI DAQ USB-6351 card. Executing
ai=analoginput('nidaq','Dev1')
returns an error (since the Legacy interface is not supported in win64?) Can I use the Session-based interface? Running
daq.getDevices
finds no supported devices (it's not a cDAQ, obviously). The USB-6351 works fine in MAX, I have the drivers (NI-DAQmx 9.3) installed (I'm using Matlab 7.12 R2011a and Data Acquisition Toolbox 2.18).
If anyone has any idea how to solve this, I'd greatly appreciate it.
Thanks!
  1 commentaire
xiaobo wu
xiaobo wu le 25 Juil 2011
what is your OS? windows 7? if the OS is windows 7, try running Matlab as admin under right click menu.

Connectez-vous pour commenter.

Réponses (1)

Manisha
Manisha le 11 Juil 2011
Hi Tomaz,
The prerelease of R2011b Data Acquisition Toolbox now supports many non-compactDAQ devices with Session-based interface.
If you have a valid MATLAB license, you can download the R2011b prerelease from here
-Manisha

Catégories

En savoir plus sur Simultaneous and Synchronized Operations dans Help Center et File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!