How can I unbalance a synchronous machine?

I need a set of stator currents of synchronous machine in an unbalanced mode. How can I get the unbalanced mode?

 Réponse acceptée

Anuj
Anuj le 29 Jan 2014

0 votes

The voltage supply equations can be changed to induce current imbalance. Suppose you are applying 3-phase voltage to the system Like Vs Sin(ωt), Vs Sin(ωt − 2π/3),Vs Sin(ωt + 2π/3), change one phase voltage to (Vs-V0) Sin(ωt) and rest same, then change other/two phase voltages.. This will induce voltage imbalance and that will further induce current imbalance.

9 commentaires

Shivakumar
Shivakumar le 4 Fév 2014
My problem is to note down the values of stator currents in balanced and unbalanced condition. Now, to the 400V, 8.1kVA, 1500RPM. I've applied 133.3 three individual 1-phase sources. I dont know why that stator currents dont come in a symmetrical way. Please help me to solve this so that stator currents come in a symmetrical way. And secondly, please explain how to unbalance. I need these solutions urgently. Thanks in advance
Anuj
Anuj le 4 Fév 2014
You will have to post your model here so that it can be seen,whats the problem, why is stator current not symmetric. and again, as i said above to unbalance, just change the magnitude of one phase voltage.
Shivakumar
Shivakumar le 5 Fév 2014
I've attached the model here. Please check.
Anuj
Anuj le 5 Fév 2014
You should apply 400V in the all 3 voltage source, not 133.3, You will get the symmetric current and to get unbalance, change one source voltage to suppose 380 and then you will see the unbalance in the stator current. I hope, it helps.
Shivakumar
Shivakumar le 17 Fév 2014
I am sorry for giving late reply. But I thank you for solving my problem.
Anuj
Anuj le 17 Fév 2014
I am glad that your problem is solved, You can accept the answer so others can be benefited too.
Regards
Shivakumar
Shivakumar le 11 Mar 2014
Anuj.. Can you please tell me why I should use only 400 volts and not 133.3?
Anuj
Anuj le 14 Mar 2014
Its a simple convention for a 3-phase supply, when you supply a 3 phase winding, you do apply a peak voltage Vm to each of the three phase, not Vm/3.