Simulink Fixed Step Size Discrete Compiler - two different step sizes in .cpp file?
Afficher commentaires plus anciens
Hi Everyone,
When I generate my code from the Simulink Coder (2011a), in my .cpp file I get
290 /* Model step function for TID0 */
291 void TEST_step0(void) /* Sample time: [0.04s, 0.0s] */
292 {
293 /* (no output/update code required) */
294 }
295
296 /* Model step function for TID1 */
297 void TEST_step1(void) /* Sample time: [1.0s, 0.0s] */
I want the step size to always be 0.04s...I set the solver to this value, and I'm not sure why it is giving me a second sample size.
thanks, B.
Réponse acceptée
Plus de réponses (1)
Daniel
le 22 Fév 2012
0 votes
I had this problem too, but I used the advanced search to look up the blocks with property "Sample time" with value "1".