Effacer les filtres
Effacer les filtres

How to decide sampling frequency (is there any rule) for analysing the 3 phase voltage and current signals so as to use them as input to neural network for fault location

1 vue (au cours des 30 derniers jours)
what should be the minimum sampling time so that short time transient peaks in power system (such as lightening surge )can be detected by the fault protection scheme(ANN based).
moreover, what is best way to feature extraction(scaling or normalization) of power signal data set so as to use them effectively to train ANN for fault detection.
  1 commentaire
Star Strider
Star Strider le 5 Mar 2014
What are the frequency characteristics of the ‘short time transient peaks’? If those are what you want to detect, their frequency spectra should determine your sampling rate. Your sampling frequency should be at least twice your highest frequency of interest.

Connectez-vous pour commenter.

Réponse acceptée

Greg Heath
Greg Heath le 24 Fév 2014
I can adequately represent one period of a sinusoidal wave with 8 equi-spaced points. So, choose the highest frequency you want to represent and start from there.
Thank you for formally accepting my answer
Greg
  2 commentaires
Greg Heath
Greg Heath le 5 Mar 2014
Plot one period of a sine wave. y = cos(t + 2*pi*rand);
Choose 8 equispaced points that cover the period
Plot the piecewise linear function represented by the 8 points
Overlay the plot on the sine-wave plot.
Not satisfied? Use more points.

Connectez-vous pour commenter.

Plus de réponses (0)