Hello,
I'm now using HDL coder to do implementation for my Zedboard. But when I usd the HDL workflow advisor, I got an error from phase 4.1. Create Project. The error message is: Faild Unable to load valid reference design plugin. I'm using MATLAB 2013b and Xilinx ISE Design Suite 14.4 Please help me to get rid of the error, thanks.

6 commentaires

Grant
Grant le 10 Juin 2014
Hello, I have the same problem, "Step 4.1 Failed, unable to load valid reference design plugin," but I am using an AXI4-Lite interface (I am trying to run the hdlcoder_led_blinking example). I am using MATLAB 2013b and Xilinx ISE 14.7. Any help troubleshooting this problem would be appreciated. Thanks, Grant
Roger
Roger le 11 Juin 2014
Hi, Grant
It seems that in the previous version before R2014a, we should have at least 1 AXI4-Lite port to get rid of the error in the step 4.1. I had this problem just because of that. As described in your situation, I don't know why it doesn't work for you.
Wang Chen
Wang Chen le 11 Juin 2014
Hi Grant,
MATLAB 2013b only support Xilinx ISE 14.4, so you see this error message in 2013b when you use ISE 14.7. Please switch to ISE 14.4 to remove this error.
Starting from R2014a, you can use ISE 14.7.
Thanks, Wang
Juan Valverde
Juan Valverde le 6 Juil 2015
Hello, I also have problems adding the Zybo platform to the HDL coder workflow advisor in Matlab 2014b. I have vivado 2015.1. do you know if they are not compatible? Besides, do you know if I need to have Vivado HLS to create an IP core?
thanks
juan
Wang Chen
Wang Chen le 6 Juil 2015
Hi Juan,
  1. 2014b HDL Coder is compatible with Vivado 2013.4.
  2. In 2015a HDL Coder, there is a shipping example about how to add Zybo platform to the HDL Workflow Advisor: Link to the example
  3. You can create an IP core using "IP Core Generation" workflow in HDL Workflow Advisor.
Thanks, Wang
Juan Valverde
Juan Valverde le 23 Juil 2015
great thank you!!

Connectez-vous pour commenter.

 Réponse acceptée

Wang Chen
Wang Chen le 25 Fév 2014

0 votes

Hi Roger, In HDL Workflow Advisor Step 1.2 "Set Target Interface", In the table "Target platform interface table", do you have one of your port assigned to "AXI4-Lite" interface?
There is a bug in R2013b MATLAB that at least one port must be assigned to "AXI4-Lite" interface in "Target platform interface table", or else Step 4.1 "Create Project" will fail on project creation. This bug is fixed in R2014a MATLAB.
Thanks, Wang

2 commentaires

Roger
Roger le 26 Fév 2014
Hi, Yes, it is just as you said, thank you!
Gökhan
Gökhan le 6 Août 2014
Hi I am using Matlab 2014a but I have still same problem. There is no choise for ise 14.7