hdl coder synchronism problem
10 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hi all, I have a problem related to synchronism of the paths of the simulink model shown in the attached figure after the simulink-vhdl conversion. As you can see from figure there is a path without any delay so after vhdl conversion this path is translated in a pure combinatorial logic while the paths with the delay are translated in a process with clock and reset in the sensitivity list. This has 2 main effects: - the overall output is asynchronous so it changes not only during the positive edge of the clock (as I want) - during the reset phase the output doesn't reset since no process with a reset is present in the path without delay. I tried to insert a zero-order hold at the input to synchronise the paths but this trick doesn't work. Any idea about my issue?? Thanks
0 commentaires
Réponse acceptée
Tim McBrayer
le 1 Mai 2014
Can you register your inputs our outputs (or both)? HDL Coder supports this via its subsystem pipelining capability; this can be implemented without modifying the Simulink diagram or changing the Simulink simulation behavior. You can access the HDL-specific settings by right-clicking on the subsystem and choosing HDL Code>HDL Block Properties.
An alternative solution, of course, is to add any necessary additional delays directly to the Simulink model.
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur HDL Coder dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!