The SrcWorkspace Name-Value pair argument to the sim() command seems to have disappeared going from 2020b to 2021a. I searched the 2021a Release Notes and could find no mention of its removal. Did I miss that in the ReleaseNotes? More importantly, how does one implement that functionality now?

Réponses (2)

Paul
Paul le 31 Août 2021
Looks like one has to use a Simulink.SimulationInput object as the input to the sim() command.
  1 commentaire
Tamas Rozsa
Tamas Rozsa le 7 Jan 2022
Modifié(e) : Tamas Rozsa le 7 Jan 2022
True.
In fact, 'SrcWorkspace' is also buggy and does not work well with data dictionaries (see e.g. https://www.mathworks.com/matlabcentral/answers/367223-using-srcworkspace-with-data-dictionaries), so Simulink.SimulationInput seems to be the way to go.
Another reason to avoid 'SrcWorkspace' might be that it seems to have issues also when using with the parallel computing command 'parfor' (see e.g. https://www.mathworks.com/matlabcentral/answers/94215-how-can-i-set-the-source-workspace-to-caller-when-using-a-the-sim-command-from-a-function-in-simul).

Connectez-vous pour commenter.


Felipe Padua
Felipe Padua le 16 Juil 2022
It's present in R2022a documentation.
  3 commentaires
Felipe Padua
Felipe Padua le 16 Juil 2022
Yes, it's very strange.
Paul
Paul le 16 Juil 2022
Just tested 2021b, and SrcWorkspace works. Good to know.