Simulink Build Error : Type mismatch in initial value

25 vues (au cours des 30 derniers jours)
Udara Darshana Panamulle Arachchige
I was getting build error as below, when I did not match the Data types.
Invalid output port data type. Data type of 'Output Port 4' of 'Integrated_HAL_BSW_ASW_ver1_05/BSW_ASW_Interface_INPUT/ASW to BSW Interface/Bus Selector1' is invalid.
The below picture shows the problematic area of my model. The output of the Stateflow is linked to the Bus selector.
Then I managed to match the data types, but now I am receiving the below error.
Type mismatch in initial value. Data 'PumpBatWp1Out_RPM' is set to be of type 'uint8' and its initial value '0' evaluated to type 'double'.
If I also have to match the initial value data type, how can I change the initial value data type? Please help me to solve this.
Thank you

Réponses (1)

Stefanie Schwarz
Stefanie Schwarz le 15 Déc 2022
Modifié(e) : Stefanie Schwarz le 15 Déc 2022
Could you try to specify uint8(0) instead of just "0" as the initial value for 'PumpBatWp1Out_RPM' in the Stateflow Symbols Pane > Property Inspector? Otherwise, it is assumed that the 0 is double. 
More information on setting data properties for Stateflow:
More information on specifying Stateflow chart data properties using MATLAB Expressions can be found here:

Catégories

En savoir plus sur Simulink Functions dans Help Center et File Exchange

Produits


Version

R2021a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by