my firing angle on this triac does not work correctly ?
9 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hi everyone, I have implemented a triac circuit with a resistive load, when I run the simulation I have 3 curve (figure 2), the problem is that the curves are wrong compared to the theory (figure 3), so surely my firing angle alpha = 36 ( figure 4) has a problem under the mask.
Guys if one of you knows how to implement a correct firing angle , explain to me plz. thanks
figure 1
figure 2
figure 3
figure 4
0 commentaires
Réponses (3)
Dr Narayanaswamy P R Iyer
le 7 Jan 2022
For switching thyristors, you may refer to the following text book:
NARAYANASWAMY P R IYER: "Power Electronic Converters Interactive Modelling Using Simulink", CRC Press / Taylor and Francis, 2018, Chapter 2.
0 commentaires
R SRIRANJANI RAMAKRISHNAN
le 8 Jan 2022
Thyristor 1 is 36 degree , then thyristor 2 is 180+36 degree with phase delay of 0.01sec.
0 commentaires
Joel Van Sickel
le 11 Jan 2022
My first guess would be that you need to double the rate of your firing. It looks like you are triggering the first thyristor correctly for the positive portion of the sine wave, but need to trigger the other thyristor for the negative side. This is what R Sriranjani Ramakrishnan is suggesting. You can either have double the rate, or add a second pule generator running at 36+180.
0 commentaires
Communautés
Plus de réponses dans Power Electronics Control
Voir également
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!