TMS320F28379D sample time for control systems
10 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
I want to control PMSM motor with TMS320F28379. Iam using Matlab examples for code generations, the PWM frequency is given as 20khz. The sampling period is set to 1/20khz=50us. Isn't there anything strangeness here? So it doesn't require several times smaller sampling time to be able to sample a 50us PWM signal? How is the sampling time of the control system sufficient?
0 commentaires
Réponses (1)
KrishnaKumar
le 14 Nov 2022
This is generally how most of the motor control algorithms are implemented. The sampling time is used for measuring currents, motor position and implementing control tasks. It is not used for sampling the PWM pulses.
However if you intend to simulate a motor model, then that model needs to have a lower sampling time if you need to observe the dynamic behaviour in detail.
0 commentaires