Noise Density and Random Walk parameters for gyroscope simulation
44 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Pablo Hidalgo Rodulfo
le 18 Jan 2022
Commenté : Ryan Salvo
le 19 Jan 2022
I am using the imuSensor (Sensor Fusion and Tracking Toolbox) to simulate a gyroscope from an inertial measurement unit (IMU).
I have to include real gyroscope parameters from a datasheet and I don't know exactly how does it match with gyroscope parameters from the toolbox:
Real Gyroscope Parameters
Noise Density (º/s) / √Hz
Angular Random Walk º/√hour
Toolbox Gyroscope Parameters
Noise Density (º/s) / √Hz
Random Walk (rad/s)(√Hz) ***
In the toolbox documentation, Noise Density corresponds to the Angular Random Walk but, in the datasheet, there is a Noise Density parameter which is quite different to the Angular Random Walk parameter.
Random Walk from toolbox is refered to Rate Random Walk (RRW), a parameter that is not given in any datasheet.
Is it necessary to include both Noise Density and Random Walk in the toolbox, or just one of them is needed to define the noise?
Which parameter from the datasheet should I use for the Noise Density in the toolbox, the Angular Random Walk or the Noise Density?
0 commentaires
Réponse acceptée
Ryan Salvo
le 18 Jan 2022
Hi Pablo,
I recommend using the Noise Density value from the datasheet for the NoiseDensity parameter for gyroparams in the imuSensor object.
The more parameters specified, the more accurate the imuSensor model will be, but only use the ones that are available to you. You are correct that the RandomWalk parameter expects the Rate Random Walk coefficient and not the Angular Random Walk one.
The imuSensor reference page has more information on how each of the parameters add noise to the model.
Thanks,
Ryan