OBSERVING SIGNAL GENERATOR OUTPUT AT HIGH FREQUENCY IN SIMULINK
6 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hi, In simulink,when i use signal generator at low frequency(egs:1 rad/sec) and observe the sine wave in a scope,my output is correct.But when the frequency is increased(egs:10 rasd/sec),the output is not correct.why is it so?Can somebody help me.
0 commentaires
Réponse acceptée
Orion
le 18 Nov 2014
Hi,
My guess is that you forget to change your simulation parameters.
In the toolbar :
Simulation -> Model Configuration Parameters.
change the solver to fixed-step, and put a small sample time to force Simulink to simulate at a desired rate.
0 commentaires
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Prepare Model Inputs and Outputs dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!