I think I found the issue. The input to th symmetrical-components transform should be complex value, but what I input is the time domain value, which is the real part of the complex value. It's a stupid mistake.
Issues of extracting instantaneous symmetrical components
8 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Raymond Wong
le 11 Avr 2022
Commenté : Mritunjaiya
le 3 Oct 2023
I want to extract 3 phase instantaneous symmetrical components, specifically, positive sequence time domain value of 3 phase. I'm using Symmetrical-Components Transform voltage. With this I can get positive, negative and zero phasors of phase A, expressed in complex number. And with the provided formula in Symmetrical-Components Transform, I'm able to get the positive phasors of phase B and C, expressed in complex number as well. The real part of the complex numbes should be the time domain value, and technically the positive sequence of 3 phase should be symmetrical components of which the angle between any 2 of them is 120°, but after I did all these manipulaitons to a unbalanced 3 phase current. The result doesn't look like they're balanced, but the 3 phase look like they're minimized from the original unbalanced components by a common factor. Is there any step I did wrong?
0 commentaires
Réponse acceptée
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Specialized Power Systems dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!