Effacer les filtres
Effacer les filtres

Simulink Error: 'Initial output' of Outport block must be a scalar

32 vues (au cours des 30 derniers jours)
Zangdaarr
Zangdaarr le 27 Jan 2015
Hi,
I'm trying to update a model from a 2009b version to 2014b and I have gone through several issues.
Now I got the following error:
[QUOTE]The parameter 'Initial output' of Outport block 'MP89/Train1/yout1' must be a scalar when the Outport block is driven by a bus signal[/QUOTE]
Here's a model picture:
Basically, a lot of bus signal are merged into a last bus creator, then a selector lead only the one I want to the output port. The output port has an initial value set in the form [x1;x2;...;xn].
This was working perfectly, but now I got this error, and I do not really understand what is meant by "scalar". I've got a scalar value for every signal in the bus. And all masked values are set to a numeric value.
Thanks for your help

Réponse acceptée

Zangdaarr
Zangdaarr le 1 Fév 2015
Seems it is no longer possible to initialize an output port value when it's driven by a bus. You have to select "inherited".

Plus de réponses (1)

Eric Duba
Eric Duba le 2 Mar 2018
Initialization is possible see: Specifing initial conditions for bus signals

Catégories

En savoir plus sur Schedule Model Components dans Help Center et File Exchange

Produits

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by