What is wrong in this model? I change parameters already.

4 vues (au cours des 30 derniers jours)
Marisa Lertvittayavivat
Marisa Lertvittayavivat le 7 Juin 2022
Réponse apportée : Tushar le 28 Sep 2023

Réponses (1)

Tushar
Tushar le 28 Sep 2023
Hi Marisa,
I understand that you are encountering issues with the task mentioned in the "Simulink Fundamentals" course. I tested the task on my end and was able to solve it. Here are a few points that may assist you:
  • In the 'Discrete Transfer Fcn' dialog box, the numerator and denominator coefficients should be listed in decreasing powers of 'z'. In this case, the Numerator and Denominator should be [Kp+Ki*Ts, -Kp] and [1, -1], respectively.
  • As stated in the task, the Initial States should be set to '0'.
  • To set the Sample Time to 'Ts', select the 'Discrete Transfer Fcn' block in the Simulink window and enter the following command in the MATLAB command window:
set_param(gcb,"SampleTime","Ts")
For more information on the 'Discrete Transfer Fcn' block and setting configuration parameters programmatically, please refer to the documentation links provided below:
I hope this information proves helpful!

Catégories

En savoir plus sur Simulink dans Help Center et File Exchange

Produits


Version

R2021b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by