The following two blocks cannot be connected in series

127 vues (au cours des 30 derniers jours)
arian hoseini
arian hoseini le 26 Juin 2022
Commenté : arian hoseini le 13 Nov 2022
i get this error and i tried to Add a high-value resistance in parallel with one of the two block but got another error
The following two blocks cannot be connected in series:
Block 1: 'Unonlinearelement_Variable Resistor/SrcI'
Block 2: 'Series RLC Branch2'
The first block, modeled as a current source, cannot be connected in series with the inductive element of the second block.
Add a high-value resistance in parallel with one of the two block.
You can also specify high-value resistive snubbers if the blocks have a snubber device.You can avoid the use of the snubber by selecting the 'Continuous' simulation type in the Solver tab of the Powergui and deselecting the 'Disable ideal switching' option in the Preferences tab of Powergui block.

Réponse acceptée

Joel Van Sickel
Joel Van Sickel le 28 Juin 2022
Hello Arian,
this is a limit based on how that block is implemented. You can either put a larger resistor in parallel with that block, or switch the solver to continuous, or you could make the circuit using simscape components instead of specialied technology, and then you won't have this limitation (the blue circuit blocks are simscape, the black ones are specialized power systems)
Regards,
Joel