Include SVPWM block in SimScape electrical example
12 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
I want to modify the following SimScape electrical example: https://www.mathworks.com/help/physmod/sps/ug/three-phase-voltage-sourced-converter-spwm.html?action=changeCountry&s_tid=gn_loc_drop
Instead of using the SPWM block, I want to use the SVPWM (2-level) generator block. As is visible from below picture, I have used multiplex and Simulink-PS-converters.
Anyhow, this does not seem to work as the phase currents are not sinusoidal anymore, as one would expect.
Can anybody tell me what is the issue here and how it can be resolved?
Parameter settings:
Repeating sequence: Time values: [0 0.05/(1000*2*pi/60*4)] Output values: [0 2*pi]
SVPWM generator: Pattern #1, Switching frequency 10.000Hz
Simulation time changed to 0.05s
All other settings unchanged, compared to simscape example
Results:

0 commentaires
Réponses (1)
Sabin
le 13 Déc 2022
Hi,
In your model I suspect the order of the PWM signals is not right.
I suggest using the PWM Generator (Three-phase, Two-level) block. This block will ask you for the switching frequency and sample time. You can check this example:
I hope this helps.
0 commentaires
Communautés
Plus de réponses dans Power Electronics Control
Voir également
Catégories
En savoir plus sur Electrical Block Libraries dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!