Importing COMSOL Data into Simscape Electrical for PMSM Modeling
There are no documented workflows. Depending on the formats in which torque and flux can be exported, it might be possible to im...
6 jours il y a | 1
how to create single switch fault in packed submodules of mmc
Probably the easiest way is to add the fault using the Gate Driver block. To model a fault in the Gate Driver block, in the Faul...
10 jours il y a | 0
Build battery pack without a thermal port
To simulate the thermal effects of the battery cell, in the Cell Properties panel, under the Cell Model Options section, set the...
12 jours il y a | 0
Simulink error: input index exceeds signal width in Park Transform block of PMSM FOC model
The Park Transform block inputs and output dimension: abc – vector of three elements, dimension 3 \theta_{elec} – dimension 1 ...
14 jours il y a | 0
The PLL (3ph) module cannot be found in the 2025b version.
Simscape Electrical provides PLL blocks in: Simscape / Electrical / Control / Measurements. The three-phase PLL: https://www.m...
15 jours il y a | 0
Specialized Power Systems to simscape solver
In Simscape, the Solver Configuration block specifies the solver parameters that your model needs before you can begin simulatio...
19 jours il y a | 2
| A accepté
Error: "Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the follow
Each physical network must have only one solver configuration block. Best practice is to put it at top level. From the diagrams ...
30 jours il y a | 0
| A accepté
Guidance on Space Vector PWM Implementation in Simulink
Simscape Electrical provides blocks for both two-level and three-level PWM generation. These blocks can be configured for space ...
30 jours il y a | 1
| A accepté
How to use bolean in simscape switch?
Use a Data Type Conversion block to convert the boolean signal to double.
30 jours il y a | 1
Hi, why aren't these circuits working?
Thyristors are unidirectional devices—they conduct only when forward-biased and triggered by a gate pulse. After conduction, the...
environ un mois il y a | 0
LLC resonant converter for Battery charging &discharging
A good starting point is Simscape Electrical. See this example as for a start: https://www.mathworks.com/help/sps/ug/dc-dc-llc-...
environ un mois il y a | 0
Why is Matlab unable to import Wolfspeed Mosfet with Diode Model?
It is not currently supported to automatically parameterize a MOSFET (or IGBT) with protection diode. To parameterize an IGBT ...
environ un mois il y a | 1
| A accepté
How to generate waveforms in MATLAB from pre-calculated converter values?
If you only want to visualize the steady-state periodic waveforms of a buck converter, using only analytical calculations, you c...
environ un mois il y a | 1
| A accepté
Simscape Multi-Domain Custom Component Icon Colors
Using svg format together with domain-specific line styles can lead to unexpected results, because domain line styles and colors...
environ un mois il y a | 0
| A accepté
How to link .m files with simscape ?
This can be done using the MATLAB Function in Simulink: https://www.mathworks.com/help/simulink/slref/matlabfunction.html
environ un mois il y a | 0
Is there such a thing as a Physical Signal Bus
As previously mentioned, there is a Simscape bus available, but it functions only with standard bi-directional physical connecti...
environ un mois il y a | 1
Where can I find practice problems using simulink?
There are now many self-paced online courses on MAthWorks website, including a few on physical modeling: https://matlabacademy....
environ 2 mois il y a | 0
Standard Overcurrent Protection Relay Block
Simscape Electrical provides an example that shows how to model an overcurrent relay in an AC microgrid: https://www.mathworks....
environ 2 mois il y a | 0
Create a Parallel RL Branch in a custom .ssc that will mimic a Parallel RL Branch Component
A good starting point is the Simscape documentation. check out this example that creates a custom resistor: https://www.mathwor...
environ 2 mois il y a | 0
Is it possible to discretize a simscape model ?
In the Solver Configuration block enable 'Use local solver'. https://www.mathworks.com/help/simscape/ref/solverconfiguration.ht...
environ 2 mois il y a | 0
Please allow simscape ports be placed at adjacent sides
This has been possible for a few years now using annotations: https://www.mathworks.com/help/simscape/lang/annotations.html
environ 2 mois il y a | 0
connecting universal bridge to subsystem block
Domain specific lines cannot be connected to Simulink inputs/outputs directly. You need to build an interface using sensors and ...
environ 2 mois il y a | 0
Why do simscape components not use branches?
The component conduction is using the base class foundation.thermal.branch (see first line): component conduction < foundation....
environ 2 mois il y a | 0
How to connect simscape block and simpowersystems block
It is not possible to connect a PS signal to an electrical domain line (or any other domain) You can use a controlled source or ...
environ 2 mois il y a | 0
What is the reason that some solvers are not available as a global solver in Simulink, but are available as a local solver in Simscape?
These solvers (Backward Euler, Trapezoidal Rule, and Partitioning) are specifically designed to handle the physical network equa...
environ 2 mois il y a | 0
How to run examples from website?
Before R2019a, if this example was available in a particular release and Simscape Electronics was installed, the command would j...
environ 2 mois il y a | 0
Fuel cell model compatibility
Since R2021a Simscape Electrical provides a Fule Cell block in Simscape technology: https://www.mathworks.com/help/sps/ref/fuelc...
environ 2 mois il y a | 0
When running ssc_build, a library is autogenerated. How do you specify that the file type is .mdl?
Only .slx format is supported by sscbuild.
environ 2 mois il y a | 0
how can i create a dynamically controlled resistance (can be controlled by a input signal) which can be connected to rotor terminal of asynchronous machine in powerlib.
A variable resistor should do this: https://www.mathworks.com/help/simscape/ref/variableresistor.html
environ 2 mois il y a | 0
How to retrieve data from the simscape results explorer.
This page should answer the question: https://www.mathworks.com/help/simscape/ref/simscape.logging.series.html For example, a m...