Why the Accuracy is changing for same data set while using Classification learner app in MATLAB.How do I get the Accuracy same for all the time
4 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Iam working with EMG signals .I found features of three signals and I need to use classfication learner app.When I use the same set of features the accuracy is varying for same validation (like cross validation and Hold out validation) with PCA.Why it is like that?
How can I get the accuracy same for all the time
0 commentaires
Réponses (1)
Walter Roberson
le 3 Août 2022
Before every run, use rng() to set the random number seed to a consistent value.
Most training systems for classifiers and neural networks use random numbers.
2 commentaires
Walter Roberson
le 4 Août 2022
for K = 1 : 5
rng(12345)
run the classification at this point
%you should get consistent answers
end