DAQ - Simulink NI myDAQ

2 vues (au cours des 30 derniers jours)
Manuel
Manuel le 12 Fév 2015
Réponse apportée : Manuel le 23 Jan 2018
Hi,
i want to measure analog and digital Signals in Simulink with an NI myDAQ Device.
http://www.ni.com/mydaq
I use a 32bit MATLAB (Data Acquisition Toolbox Version 3.6 R2014b) in a 64bit Windows 7 PC. The Support Package is installed too.
http://de.mathworks.com/hardware-support/ni-mydaq.html
Device (myDAQ) works with NI Software without problems
devices =
ni: National Instruments NI myDAQ (Device ID: 'myDAQ1')
Analog input subsystem supports:
-2.0 to +2.0 Volts,-10 to +10 Volts ranges
Rates from 0.1 to 200000.0 scans/sec
2 channels ('ai0','ai1')
'Voltage' measurement type
Analog output subsystem supports:
-2.0 to +2.0 Volts,-10 to +10 Volts ranges
Rates from 0.1 to 200000.0 scans/sec
2 channels ('ao0','ao1')
'Voltage' measurement type
Digital subsystem supports:
8 channels ('port0/line0' - 'port0/line7')
'InputOnly','OutputOnly','Bidirectional' measurement types
Counter input subsystem supports:
Rates from 0.1 to 100000000.0 scans/sec
1 channel ('ctr0')
'EdgeCount','PulseWidth','Frequency','Position' measurement types
Counter output subsystem supports:
Rates from 0.1 to 100000000.0 scans/sec
1 channel ('ctr0')
'PulseGeneration' measurement type
>> daqhardwareinfo = daqhwinfo
daqhardwareinfo =
ToolboxName: 'Data Acquisition Toolbox'
ToolboxVersion: '3.6 (R2014b)'
MATLABVersion: '8.4 (R2014b)'
InstalledAdaptors: {3x1 cell}
>> daqinstalledadaptors = daqhardwareinfo.InstalledAdaptors
daqinstalledadaptors =
'nidaq'
'parallel'
'winsound'
>> daqregister('nidaq')
ans =
'mwnidaq.dll' successfully registered.
but i cant select the device in Simulink :(
any ideas whats wrong? what should i do? do you need more information?
thanks mscharff
  1 commentaire
Ali Zolfagharian
Ali Zolfagharian le 16 Mar 2017
Hi Manuel,
Could you find the answer to your question? I have the same problem but still waiting for a help.

Connectez-vous pour commenter.

Réponses (4)

Manuel
Manuel le 16 Fév 2015
is the following Information correct?
from
https://www.linkedin.com/groups/How-interface-NImyDAQ-Matlab-134533.S.227913757
" Ivan M.
Application Engineer - The MathWorks
It's because myDAQ use Session Interface, meanwhile the blocks in Data Acquisition Toolbox that support Simulink are available only for data acquisition devices that can be used with the legacy interface.
"
Any Idea/Samples/Papers what i can do?
  1 commentaire
BingQian YAN
BingQian YAN le 28 Juin 2015
Nice, true.thx

Connectez-vous pour commenter.


Christian
Christian le 10 Déc 2015
Hey, I am facing the same Problem. Is there a way to do Simulink session based data acquisition? Regards Chris

Ali Zolfagharian
Ali Zolfagharian le 16 Mar 2017
Hi,
Is there any way to use myDAQ in Simulink? Since I have the same problem.

Manuel
Manuel le 23 Jan 2018
https://de.mathworks.com/matlabcentral/answers/330174-ni-mydaq-simulink-toolbox

Catégories

En savoir plus sur Data Acquisition Toolbox Supported Hardware dans Help Center et File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by