Connecting two ZYNQ706using single MATLAB window

2 vues (au cours des 30 derniers jours)
muhammad ahmad
muhammad ahmad le 23 Août 2022
Commenté : muhammad ahmad le 26 Août 2022
I am trying to connect two ZYNQ706 to a single computer i have changed the ip address of one ZYNQ board but when i try to connect both ZYNQ board simultaneously it assign the same IP to both board how is it possible to connect both ZYNQ using different IP address
  2 commentaires
Steve Kuznicki
Steve Kuznicki le 25 Août 2022
Modifié(e) : Steve Kuznicki le 25 Août 2022
You will need to edit the "interface" file on each of the ZC706 SD-Cards. In there you should assign a different static IP Address to each board. This is assuming that you have an Ethernet switch or 2 USB-to-Ethernet adaptors and you are using a static IP Address for your host side as well.
e.g.
# interface configuration
auto lo eth0
iface lo inet loopback
# eth0: Static configuration
iface eth0 inet static
# host address is 192.168.2.1
# 2nd ZC706 has address 192.168.2.3 here
address 192.168.2.2
netmask 255.255.255.0
gateway 0.0.0.0
muhammad ahmad
muhammad ahmad le 26 Août 2022
I already have assigned different ip address to both ZYNQ as
Zynq1=192.168.3.2
Zynq2=192.168.30.2
both are working when we run through normal simulink file simultaneously but when we run softwre interface model on both zynq simultaneously ony one zynq work at one time i need to instentiate so that both zynq run simultaneously