System Identification toolbox, can't import frequency domain data above frequency of pi rad/s
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Olav W. Alstad
le 24 Fév 2015
Commenté : Olav W. Alstad
le 24 Fév 2015
I'm using the System Identification toolbox to approximate a transfer function from frequency domain data. The data is numerical values of a frequency function (complex) in the range of 0.63 rad/s too 94.25 rad/s (0.1 Hz - 15 Hz). The problem is that frequency function above pi rad/s (3.14 rad/s) will not be imported. If the frequency is scaled down, such that the max frequency is lower than pi rad/s, the whole frequency function is sucsessfully imported.
It might be a simple answer to this question, but I've no idea. Thanks for helping me :)
0 commentaires
Réponse acceptée
Arkadiy Turevskiy
le 24 Fév 2015
You are forgetting to set the sample time somewhere in your code or in the app. The tool will show the data up to the Nyquist frequency. So if you leave sample time at default Ts=1 sec, that would be 0.5*(1/Ts)*2pi=pi rad/sec.
D you know the sampling time your data was collected at? Say if it was 100 samples/sec, Nyquist frequency would be 0.5*(100)*2*pi=314 rad/s, allowing you to see all your data.
Plus de réponses (0)