about nonvirtual subsystem,how to solve it

11 vues (au cours des 30 derniers jours)
LIU shengxiang
LIU shengxiang le 17 Mar 2015
Réponse apportée : MULI le 15 Avr 2025
Connections of the Physical Network cross nonvirtual boundaries. If any blocks in a Physical Network are within a nonvirtual subsystem, then all blocks of that network must be in the same nonvirtual subsystem. Either move affected blocks out of the nonvirtual subsystem, move network blocks into exactly one nonvirtual subsystem, or reconfigure affected nonvirtual subsystems to be virtual subsystems.
  3 commentaires
Ammon McCarthy
Ammon McCarthy le 16 Avr 2020
Hi, I also have this problem. Was this taken care of?
Thirumala
Thirumala le 4 Avr 2025
Any solution?

Connectez-vous pour commenter.

Réponses (1)

MULI
MULI le 15 Avr 2025
The error you are observing "Connections of the Physical Network cross nonvirtual boundaries..." is a known limitation which can be found in the below MathWorks documentation link:
Instead, you can try one of the following solutions:
  1. Make all related subsystems virtual (Right-click the subsystem → Subsystem Parameters → Uncheck "Treat as atomic unit")
  2. Move all physically connected blocks into a single nonvirtual subsystem
  3. Move all physical network blocks to the top level of the model.

Tags

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by