Not able to use the if condition as desired in simulink

1 vue (au cours des 30 derniers jours)
Sandesh Venkatesh
Sandesh Venkatesh le 21 Nov 2022
Réponse apportée : Paul le 21 Nov 2022
The purpose of this blocks is to check whether the input is zero if it is true then a particular rate limiter will be applied if not then other rate limiter to be applied. However, I am not able to execute the attached image simulink block as it gives the error stating that 'if can be connected to only one action subsytem and may not be connected to more than one action subsystem'. Can someone let me know what am I doing wrong.
Thanks in Advance

Réponse acceptée

Benjamin Thompson
Benjamin Thompson le 21 Nov 2022
You need to use the "if action" subsystem along with the "if". See the example in the documentation:

Plus de réponses (1)

Paul
Paul le 21 Nov 2022
The outputs of an If block can only drive If-Action subsystems. At a minimum, the limiter blocks need to be wrapped inside If-Action subsystems. See the linked doc page and the links from there for more info.

Catégories

En savoir plus sur Subsystems dans Help Center et File Exchange

Produits


Version

R2020a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by