Simulink.B​lockDiagra​m.arrangeS​ystem does not work inside library

1 vue (au cours des 30 derniers jours)
Manuel K
Manuel K le 30 Nov 2022
Modifié(e) : Manuel K le 1 Déc 2022
Hello,
I'm using the command:
Simulink.BlockDiagram.arrangeSystem(gcb,FullLayout='true');
to sort and rearrange the blocks inside a masked subsystem. This worked fine until I converted this subsystem into a library block.
Now this command does nothing and the internal structure remains cluttered and unreadabel. Because this blocks heavily modifies itself, I can't establish a pleasant alignment beforehand.
Is there any way to get this working?
  4 commentaires
Fangjun Jiang
Fangjun Jiang le 30 Nov 2022
Sorry, to be acurate, for the library block, I shall refer it as "is the LinkStatus inactive".
Manuel K
Manuel K le 30 Nov 2022
Also no.

Connectez-vous pour commenter.

Réponses (1)

Fangjun Jiang
Fangjun Jiang le 30 Nov 2022
I've tried it. You need to disable the library link first.
set_param(gcb,'LinkStatus','inactive')
Simulink.BlockDiagram.arrangeSystem(gcb,FullLayout='true')
  2 commentaires
Manuel K
Manuel K le 1 Déc 2022
Although that's working, I don't want to keep the 'LinkStatus' in the 'inactive' state.
(Restoring it isn't possible because the local instance has different blocks inside, which will get deleted.)
Manuel K
Manuel K le 1 Déc 2022
Modifié(e) : Manuel K le 1 Déc 2022
Since the command only works the first time after placing the library-block (as mentioned in my comment above), my workaround is the following:
Everytime I need to change / update a setting inside the mask of the librry-block, I place a new instance and delete the old one.

Connectez-vous pour commenter.