Fmu with “canBeInst​antiatedOn​lyOncePerP​rocess” = false

4 vues (au cours des 30 derniers jours)
Claire
Claire le 19 Déc 2022
Modifié(e) : Yash le 23 Sep 2024
I would like to create an fmu from a simulink model where the “canBeInstantiatedOnlyOncePerProcess” fmu variable is set to false rather than true. Is there a way to set this?

Réponses (1)

Yash
Yash le 23 Sep 2024
Modifié(e) : Yash le 23 Sep 2024
The canBeInstantiatedOnlyOncePerProcess flag in modelDescription.xml can be set to true or false for a Simulink model with fixed-step solver by either:
1) Using CLI: By setting the value of parameter SupportMultiInstance as on or off in the function exportToFMU (https://www.mathworks.com/help/slcompiler/ref/exporttofmu.html#mw_543093a5-7db7-4a99-82fa-2ab09dbc03c6) The flag is set to false when this parameter is specified as on.
2) From GUI: By selecting the check box "Support multiple instantiation per process" in the Advanced tab of Export Model to Standalone FMU
This functionality seems to have been supported since MATLAB R2024b by MathWorks and is compatible with FMI 2.0 and 3.0 standards.

Catégories

En savoir plus sur RF Blockset Models for Transceivers dans Help Center et File Exchange

Tags

Produits


Version

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by