Effacer les filtres
Effacer les filtres

MPC output(mv) is zero

4 vues (au cours des 30 derniers jours)
Shivam Bajpai
Shivam Bajpai le 26 Déc 2022
Good evening, everyone,
I am currently working on the path following simulink model using MPC controller. The parameters are:
mo:3(current states-x,y, theta)
ref:3(reference states-x,y, theta)
mv:(linear velocity, angular velocity)
Simulink model is working without any error but the outputs(mv) from the MPC controller are zero only. I don't know why it is so. Kindly help me with it. I have applied constraints and designed the parameters. I have attached the picture of mymodel below.
  1 commentaire
Emmanouil Tzorakoleftherakis
I suspect the optimization is not converging. Can you check what the optimization status is? You can enable this port directly from the MPC block

Connectez-vous pour commenter.

Réponses (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by