How to reset the label range for a heatmap?

3 vues (au cours des 30 derniers jours)
Tianming Qu
Tianming Qu le 9 Jan 2023
Commenté : Tianming Qu le 9 Jan 2023
Hi all,
I am new to Matlab, could anyone help me on how to reset the label range of a heat map?
Following is my code and my result fig
T=readtable('water_density_map_cumulative_10172022/7500.dx.csv');
A = table2array(T);
A_interp = interp2(A,7);
colormap turbo
!imagesc(A_interp);
colorbar()
I2disp = A_interp;
I2disp(I2disp(:)<0.009) = nan;
pcolor(I2disp([1:end,end],[1:end,end])),shading flat,axis ij
The heatmap form is 4000*4000 and the fig label is just 0-4000 for both x and y, however I want it range from, 0-30, is there any way I can do this?
Thanks for any help!

Réponse acceptée

dpb
dpb le 9 Jan 2023
Sure. Use the alternate form for pcolor with the requested X, Y coordinates...
C=I2disp([1:end,end],[1:end,end]; % a temporary for convenience
[nR,nC]=size(C);
X=linspace(0,30,nC);
Y=linspace(0,30,nR);
pcolor(X,Y,C)
  6 commentaires
dpb
dpb le 9 Jan 2023
Glad to...moral is we can't fix what we can't see... :)
If the Answer provided the solution to the Q?, please Accept it if for no other reason to let others know it isn't still pending...
Tianming Qu
Tianming Qu le 9 Jan 2023
I just accepted it as the answer. Thanks for the help

Connectez-vous pour commenter.

Plus de réponses (0)

Catégories

En savoir plus sur Data Distribution Plots dans Help Center et File Exchange

Produits

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by