NI DAQ channel terminal in MATLAB is read-only
Afficher commentaires plus anciens
Hello, I am using an NI-9422 to read in a signal for motor speed. I am reading in through the data acquisition toolbox in MATLAB. I can read the frequency fine for 1 terminal but I am struggling to understand how to read multiple terminals or a specific terminal.
For instance, the current assigned terminal is PFI5 and if I try to assign a variable ch to my channel and then re-assign the ch.terminal as PFI7 it says it's read only. I've also unplugged, and plugged the chassis back in and the default terminal changes which I can only solve by moving my wires.
What am I missing? Thanks for any help.
Réponse acceptée
Plus de réponses (1)
chrisw23
le 28 Fév 2023
0 votes
As long as the PFI is configured as Input it should be readOnly.
Each PFI line can be individually configured as a static digital input or a static digital output.
Check the current I/O state.
4 commentaires
Hyalex Ortho
le 28 Fév 2023
chrisw23
le 1 Mar 2023
no way, but as long a s you try to write to an input you will receive a 'read only' warning
Hyalex Ortho
le 1 Mar 2023
chrisw23
le 1 Mar 2023
I'm not using the DataAcqToolbox but the DAQmx API instead but I think it is similar.
When you define the task you have to add all channels you want to use and you can't get access to a channel that is not defined for that task.
i.e.
obj.ContinuousAnalogInTask.AIChannels.CreateVoltageChannel(...
% physicalChannelName
% nameToAssignChannel (alias)
% enum NationalInstruments.DAQmx.AITerminalConfiguration
% minimumValue
% maximumValue
% NationalInstruments.DAQmx.AIVoltageUnits
Catégories