I tried to set RelTol and MaxStep parameters for parsim, but simulation manager said Invalid setting for block_diagram parameter 'RelTol'. How should I set those? Thanks for any help.
simIn = simIn.setModelParameter("StopTime", 'simStopTime', 'RelTol', 1e-3, 'MaxStep', 1/fs);
simOut = parsim(simIn, 'ShowSimulationManager', 'on', 'CleanupFcn', @Simulink.sdi.clear, 'TransferBaseWorkspaceVariables', 'on')
0 commentaires
Réponse acceptée
Abhijeet
le 7 Mar 2023
Hi,
The RelTol and MaxStep parameters are not block diagram parameters, but rather solver parameters in Simulink. Therefore, it is required to set them using the setSolver method of the Simulink.SimulationInput object before passing it to the parsim function. Here's an example of how to set these parameters:
simIn = simIn.setModelParameter("StopTime", 'simStopTime');
simIn = simIn.setSolver('RelTol', 1e-3, 'MaxStep', 1/fs);
simOut = parsim(simIn, 'ShowSimulationManager', 'on', 'CleanupFcn', @Simulink.sdi.clear, 'TransferBaseWorkspaceVariables', 'on');
Note that the setSolver method sets the solver parameters for all blocks in the model, so please make sure that the values set are appropriate for the specific model and simulation requirements.