issues on Heat exchanger in simscape TL-MA
6 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
carlo ferro
le 22 Mai 2023
Commenté : Yifeng Tang
le 26 Mai 2023
the model created seems not to behave phisically correct: heat exchanger reduces both temperature of TL and moisture air.
it should heat up air, cooling down fluid instead.
7 commentaires
Réponse acceptée
Yifeng Tang
le 26 Mai 2023
Setting reasonable parameters to discribe the nominal conditions for the heat exchanger seem to resolve the issue. Pay particular attention to units and type of information needed (mass flow vs. volumetric flow). The port size matters as well because the local velocity calculated based on port size and mass flow is also part of the energy flow calculation.