Simulink Missing Reference Error
8 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hello, I'm not a novice at MATLAB but I am at simulink, and my code keeps claiming that its missing a reference, when i DO have a reference. I'm wondering if someone could shed some light on the subject.
Here's the error: Number of variables exceeds number of equations. Check for missing reference node.
From what I've ready you need a solver block for each domain, and i should only have one electrical domain. I've tried removing parts till it works but so far this is as smiple as i could make it without destroying the idea I'm trying to simulate.
Thanks! Dustin
0 commentaires
Réponse acceptée
Guy Rouleau
le 29 Oct 2011
The Controlled PWM voltage block is sort of special. The 2 sides are independent, so you must have a ground on each side.
Add a ground on the side where you only have a source.
I recommend contacting technical support with your model to request a more relevant error message.
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Electrical Sensors dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!