how to set a lowpass filter in simulink?

4 vues (au cours des 30 derniers jours)
moh mor
moh mor le 22 Juin 2023
Commenté : Paul le 23 Juin 2023
I want to design a lowpass filter in simulink. my sampling frequency is 1000 Hz and I want to have transition band between 120 Hz and 880 Hz in order to make my reconstruction filter for DAC, as per to the following picture:
my setting for lowpass filter is in the following, but it arises the represented error:
I decided to use filter designer part in MATLAB. but in addition to the fact that it does not allow you to exceed transition beyond half of sampling frequency, it gives you error: "filter error must be 3 or more." . settings are shown in the following:
what can I do then?
any help would be appreciated.
Thanks.

Réponses (1)

Paul
Paul le 22 Juin 2023
Hi moh mor,
The error message from the Lowpass Filter block sounds bit misleading.
If you look on the doc page, it says that the passband and stopband edges must be less than half the Input sample rate. The Stopband edge of 880 Hz is more than half the Input sample rate of 1000 Hz; I suspect that's the problem.
Under the hood, the filter design probably normalizes everything so that 1 corresponds to half the input sample rate, hence the wording of the error message. Just guessing about that.
  2 commentaires
moh mor
moh mor le 23 Juin 2023
Thanks. Your first point was correct. Anyway, is not there any option to use filter within 0 to Fs? this makes my filter more relaxed.
Paul
Paul le 23 Juin 2023
I'm not quite sure what this means: "use filter within 0 to Fs". I'm pretty sure you can only specify the frequency response at frequencies 0 < F < Fs/2 because the frequency response has to satsisfy certain symmetry properties at all frequencies outside that range.