How do I address issue with width and dimension of PI i simulink

7 vues (au cours des 30 derniers jours)
Manasseh Shitta
Manasseh Shitta le 27 Juin 2023
Commenté : Boris le 27 Mai 2025
I am working on validating a model for my project, the simulink built and return two (2) errors similar to each other as written below
=== Simulation (Elapsed: 6 sec) ===
Error:Error in port widths or dimensions. 'Output Port 1' of 'Emma/PLL/Model/Continuous PID/Kp6' has 3 elements. This port does not accept the dimensions (or orientation) specified by the output signal.
Error:Error in port widths or dimensions. Invalid dimension has been specified for 'Input Port 1' of 'Emma/PLL/Model/Continuous PID/Transfer Fcn'.
  2 commentaires
Nikhil
Nikhil le 27 Juin 2023
Can you share the model to reproduce the issue?
Manasseh Shitta
Manasseh Shitta le 30 Juin 2023
@Nikhil See the model as requested for kind assistance

Connectez-vous pour commenter.

Réponse acceptée

Nikhil
Nikhil le 5 Juil 2023
The error occurs because PLL block accepts only one sinusoidal signal as input. To use it for the case of three phase Voltages/Currents, you can use a PLL (3ph) block.
Refer to this documentation, for more information on the PLL block. Also, look into the example attached in the article, which showcases the use of PLL and PLL(3ph) blocks.
Additionally refer to this article for information on PLL(3ph) block.
  2 commentaires
Manasseh Shitta
Manasseh Shitta le 5 Juil 2023
I appreciate it Nikhil, I would try it out and give you feedback. Thank you
Boris
Boris le 27 Mai 2025
Have you been able to tackle thet issue?
I've been having the same error, but I do not use the PLL block, I feedt the loaded data into an adder, which should handle any incoming vector.