Modeling dissociation using Hill function provides misleading results
Afficher commentaires plus anciens
I stumbled upon a simple dissociation model using Hill function. The process in question is
[A:B] -> A + 2 B
A, B, [A:B] species [nanomole]
Now, dependent on how one formulates it mathematically, the results are completely different.
Case 1: Vmax/((EC50/[A:B])^n+1)
Vmax = 1.2 [nanomole/hour]
EC50 = 10 [nanomole]
n = 2 [-]
Simulation produces figure 1.

Case 2: Vmax/((EC50/([A:B]/comp1))^n+1)
Vmax = 1.2 [nanomole/hour]
EC50 = 10 [nanomole/liter]
n = 2 [-]
comp1 = 1 [microliter]
Simulation produces figure 2.

The question I am wandering about why in the second case the amount becomes negative.
sbproj files attached. Any comments would be appreciated. Emjey