- Ignore the messages because you know they don't matter to you.
- Make sure the values for those variables are not changed. The change won't have effect anyway, because those variables are non-tunable. The value for those variables are built into the fast restart optimization. Maybe the change was made by mistake?
- Set those variables to be tunable. Then the change of value will impact the simulation result.
Not suppressable warnings in Simulink
3 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hi,
I have the following issue:
"The message identifier Simulink:Engine:NonTunableVarChangedInFastRestart cannot be suppressed."
Why is it not possible and when will it be fixed?
Is there a workaround?
I just don't want to see those messages. There is more important information to be displayed.
BR
Christian
0 commentaires
Réponses (1)
Fangjun Jiang
le 10 Août 2023
Between fast restart simulations, you have some variables that have changed their values. But these variables are non-tunable. That is why the warning messages popped up.
Your options:
3 commentaires
Walter Roberson
le 10 Août 2023
The variables are saved in a struct.
Create one struct for the tunables and a different struct for the non-tunables.
Voir également