Change of frequency content after using the retime function
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hi everyone,
I am using the retime function to downsample a set of data. I was surprised when I saw that after using the function, the frequency content of the data has changed. It doesn't do that if I filter the data before retiming:
Could someone explain this phenomena to me?
Thanks!
I include the code below:
dt1 = seconds(test_table.time(2) - test_table.time(1));
dt2 = 0.01;
dt = seconds(dt2);
test_table_rt = retime(test_table,'regular','linear','TimeStep',dt);
%% Try after filtering
test_table_f = lowpass(test_table, 10); % Filter down to 10 Hz
test_table_frt = retime(test_table_f,'regular','linear','TimeStep',dt);
%% Plot the differences:
figure
plot(test_table.time, test_table.data)
hold on
plot(test_table_rt.time, test_table_rt.data)
plot(test_table_frt.time, test_table_frt.data)
%% Plot the different spectra
figure
ax = gca;
window = 1000;
[pxx,f] = pwelch(test_table.data,window*dt2/dt1,[],[],1/dt1);
plot(f,pxx, 'DisplayName', 'Original');
hold on
[pxx,f] = pwelch(test_table_rt.data,window,[],[],1/dt2);
plot(f,pxx, 'DisplayName', 'Retimed');
[pxx,f] = pwelch(test_table_frt.data,window,[],[],1/dt2);
plot(f,pxx, 'DisplayName', 'Filtered and retimed');
ax.XScale = 'log';
% ax.YScale = 'log';
grid on
grid minor
legend
xlabel('Frequency, Hz')
ylabel('PSD, dB/Hz')
xlim([1 50])
0 commentaires
Réponses (2)
Sulaymon Eshkabilov
le 17 Nov 2023
Here is how to solve this issue:
load('question_data.mat')
dt1 = seconds(test_table.time(2) - test_table.time(1));
dt2 = 0.01;
dt = seconds(dt2);
% Averaging is necessary here before resampling
test_table_rt0 = retime(test_table,'secondly','mean');
% Resampling is done after averaging
test_table_rt = retime(test_table_rt0,'regular','linear','SampleRate',100);
% Try after filtering
test_table_f = lowpass(test_table, 10); % Filter down to 10 Hz
test_table_frt = retime(test_table_f,'regular','linear','TimeStep',dt);
%% Plot the differences:
figure
plot(test_table.time, test_table.data)
hold on
plot(test_table_rt.time, test_table_rt.data)
plot(test_table_frt.time, test_table_frt.data)
%% Plot the different spectra
figure
ax = gca;
window = 1000;
[pxx,f] = pwelch(test_table.data,window*dt2/dt1,[],[],1/dt1);
plot(f,pxx, 'DisplayName', 'Original');
hold on
[pxx,f] = pwelch(test_table_rt.data,window,[],[],1/dt2);
plot(f,pxx, 'DisplayName', 'Retimed');
[pxx,f] = pwelch(test_table_frt.data,window,[],[],1/dt2);
plot(f,pxx, 'DisplayName', 'Filtered and retimed');
ax.XScale = 'log';
% ax.YScale = 'log';
grid on
grid minor
legend
xlabel('Frequency, Hz')
ylabel('PSD, dB/Hz')
xlim([1 50])
Peter Perkins
le 17 Nov 2023
Julius, I'm definitely not any kind of signal processing expert, but I think what you want is resample, from the Signal Processing Tbx.
If I replace this
%test_table_f = lowpass(test_table, 10); % Filter down to 10 Hz
%test_table_frt = retime(test_table_f,'regular','linear','TimeStep',dt);
in your code with this
test_table_frt = resample(test_table,1,10);
test_table_frt.Properties.DimensionNames(1) = "time"; % just cosmetics to make code below this work
I get this:
1 commentaire
Peter Perkins
le 17 Nov 2023
Modifié(e) : Peter Perkins
le 17 Nov 2023
It is perhaps not clear enough in the doc for retime, but this
dt1 = <ms time step, so .001>
dt2 = 0.01;
dt = seconds(dt2);
test_table_rt = retime(test_table,'regular','linear','TimeStep',dt);
just takes every 10th point. Often when you do downsampling like that you'd want 'mean', not 'linear', but I think you are concerned with frequency content and that's what resample is all about.
I've made a note to add some more information about this to the resample doc page.
Voir également
Catégories
En savoir plus sur Spectral Estimation dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!