Simulating for U channel cooling system using own battery pack.
4 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Error:Error compiling Simscape network for model BatteryWithCollingPlate.
Caused by:
Connection 'connect(Module1.BottomExtClnt,U_shaped_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x1' and '1x42'. The arguments in a connection must be of the same size.
0 commentaires
Réponse acceptée
Kautuk Raj
le 14 Fév 2024
Déplacé(e) : Joel Van Sickel
le 20 Fév 2024
I suggest verifying the the sizes of the ports on both components (Module1.BottomExtClnt and U_shaped_Channels.Side1). As the error message states, to resolve this issue, you need to ensure that the ports being connected have the same size.
You can share your Simulink model BatteryWithCollingPlate here for a better understanding.
1 commentaire
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Get Started with Simscape Battery dans Help Center et File Exchange