The selection in my bus selector not selecting option from dro down

5 vues (au cours des 30 derniers jours)
Emmanuella
Emmanuella le 23 Fév 2024
Réponse apportée : Sayan le 15 Mar 2024

In my design of a single phase induction motor, my bus selector option is not showing stator measurements, rotor measurement and others as it is meant to

 but displaying nothing just signal 1 and signal 2. I don't know why, any help would be appreciated as it is needed for my design 

Réponses (1)

Sayan
Sayan le 15 Mar 2024
Hi Emmanuella,
I can see the Bus selector in the first image is not connected to the measurement port of the Single Phase Asynchronous Machine. If the measurement parameters are still not shown in the Bus selector after connecting to the measurement port and completing the circuit, try to update the model. You can do this by pressing Ctrl+D. It should update the measurement parameters in the Bus selector.
However, if the issue still persists, please share the model for further investigation. You may find this example model containing "capacitor-start" and "capacitor-start-run" Single Phase Asynchronous Machines useful.
You can find more information on the Single Phase Asynchronous Machine in the following documentation.
Hope this helps in resolving the issue.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by