Effacer les filtres
Effacer les filtres

Stop Simulink Model Update via Callback

2 vues (au cours des 30 derniers jours)
RIchard
RIchard le 15 Avr 2024
Modifié(e) : RIchard le 16 Avr 2024
I have a callback on a custom block that checks a bus selector for missing signals, at the start of the model update routine. Based on the results of that update, I send an sldiagviewer.reportError(errMsg) command to Matlab. What I want it to do is stop the update cycle at that point because I know it will throw an error downstream in ~5 minutes where the user will have to fix the problem. Instead, Simulink just continues runnign the update cycle until Simulink decides it cannot continue anymore.
So my question is basically how to stop the update cycle?

Réponse acceptée

Fangjun Jiang
Fangjun Jiang le 15 Avr 2024
Instead of sldiagviewer.reportError(errMsg), if you do error(errMsg), it should stop.
  3 commentaires
Fangjun Jiang
Fangjun Jiang le 15 Avr 2024
Modifié(e) : Fangjun Jiang le 15 Avr 2024
okay, try modelName([],[],[],'term'). I think model update is equivalant as modelName([],[],[],'compile')
RIchard
RIchard le 16 Avr 2024
Modifié(e) : RIchard le 16 Avr 2024
Your orignal comment is correct and I have accepted it. Somehow, I was incorrectly calling `error`, and it was going to the matlab version instead of simulink.

Connectez-vous pour commenter.