PID Tuning tells me the system has closed loop stability even though it doesn't
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hello everyone,
I am using the PID Tuning App to design a PID controler for my plant. It works pretty good, the systems reaction is pretty solid and the PID Tuning tells me that I have closed loop stability.
The problem is, when I check the root locus, it has some poles with positive real values, indicating my system is unstable. There is even a branch that is not reaching into the negative pane, so it would seem impossible to stabilize the system.
Also, if I design the controler with the "sisotool", I get the same result.
Is there something I might be missing?
Thank you in advance for any help!
Is it sometimes acceptable to work with a system even though it is not stable?
0 commentaires
Réponses (1)
Arkadiy Turevskiy
le 24 Avr 2015
If not, then please attach your models/files- hard to troubleshoot otherwise.
0 commentaires
Voir également
Catégories
En savoir plus sur PID Controller Tuning dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!