Effacer les filtres
Effacer les filtres

switching of svpwm is not working . it is not showing staircase mode in scope

28 vues (au cours des 30 derniers jours)
PARADESI
PARADESI le 13 Août 2024 à 9:38
Commenté : PARADESI le 16 Août 2024 à 5:58

Réponse acceptée

Fangjun Jiang
Fangjun Jiang le 13 Août 2024 à 12:27
Modifié(e) : Fangjun Jiang le 14 Août 2024 à 12:53
To convert radians to degree, the Gain should be 180/pi. You had it as pi/180. That seems to be the cause.
The logic seems correct, although a single Lookup Table block can replace all those blocks, mapping 0~60 to 1, 60~120 to 2, etc.
  1 commentaire
PARADESI
PARADESI le 16 Août 2024 à 5:58
thank you
i have the stair case for the svpwm.
for the three phase grid connected system should i have used the angle from pll and i'm experiencing exponentially increasing waveform. what should i do to settle it down

Connectez-vous pour commenter.

Plus de réponses (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by